Configuring ATM Networks

This article describes how to configure Linux-based PCs and an asynchronous transfer mode (ATM) switch to build on ATM network.

The Linux ATM software (device driver and utilities) is developed and supported by Werner Almsberger in Switzerland as part of the Linux-ATM API software set (see Resources). This software contains device drivers for the following ATM adapters: Efficient ENI-155P, SMC ATM Power 155, Rolf Fiedler's TNETA1570 board, Zeitnet ZN1221/ZN1225 and the IDT 77901/77903 155 and 25 Mbps adapters. Also, a driver for the Fore PCA-200E ATM adapter is available separately (see Resources). The two adapters I have experience with are the Efficient ENI-155p and the Fore PCA-200E.

The National Institute of Standards and Technology (NIST) uses ATM and Fast-Ethernet networks as interconnects in its scalable cluster computing initiative. One research area is evaluating the benefits of ATM and Fast-Ethernet networks in this cluster environment.

In this article, I will tell you how to obtain and install the ATM support software and device drivers. I will also describe how to configure the ATM connections on the PCs and the switch to be used for IP network traffic.

The ATM interface cards I use are ENI-155P ATM adapters produced by Efficient Networks and PCA-200EPC adapters from Fore Systems. These cards are installed in standard Pentium or Pentium-Pro-based PCs running Linux. The ATM switch I used for this article is a Fore ASX-1000, although the information I give applies to all of the Fore ATM switches. This switch can be set up to allow the Linux workstations to use IP over both Switched Virtual Circuits (SVC) and Permanent Virtual Circuits (PVC).

Obtaining and Installing the Linux-ATM Software

The ATM software is available from http://lrcwww.epfl.ch/linux-atm/. The software is packaged as a compressed, gzipped tar file. Each version of the software is tied to a specific version of the Linux kernel. For this article, I used version 0.35 running on Linux kernel 2.1.90. The size of the ATM software distribution is roughly 500KB. The device driver for the Fore PCA-200E adapter can be obtained by anonymous FTP from ftp://os.inf.tu-dresden.de/pub/pca200e/. Refer to the README file in the PCA200 distribution for further information.

The driver portion of the Linux-ATM software, as well as the changes to the Linux kernel, are shipped as one large patch file. Therefore, adding support to the Linux kernel for ATM is straightforward: apply the kernel patch, configure and rebuild the kernel in the usual way. The ATM configuration items you must have are:

  • Asynchronous Transfer Mode (ATM) (CONFIG_ATM)

  • Classical IP over ATM with ATMARP (CONFIG_ATM_ATMARP)

  • Device driver, one of the following:Efficient Networks ENI155P (CONFIG_ATM_ENI)ZeitNet ZN1221/ZN1225 (CONFIG_ATM_ZATM)Rolfs TI TNETA1570 (CONFIG_ATM_TNETA1570)IDT 77201 (NICSTAR) (CONFIG_ATM_NICSTAR)

I recommend starting with a fresh Linux kernel source tree before applying the ATM patch. Refer to the USAGE file that is part of the Linux-ATM software, as things may change. All of the device drivers in the distribution can be built as kernel modules or as part of the kernel object itself. If you are using a Fore PCA-200E adapter, you do not select a driver during the kernel configuration. The PCA-200E device driver is built as a module separately, as specified in the README file included in the PCA200 distribution.

After the kernel is patched, rebuilt and installed, you are ready to build the ATM support software. Again, refer to the instructions in the USAGE file. One change I recommend is installing the support files in /usr/local/atm-version/bin and creating a soft link from /usr/local/atm to the actual install directory. By using the soft link, you can change ATM software levels and back them out, if needed, without changing the configuration scripts.

Configuring the ATM Device Interface

You are now ready to configure the IP over ATM. First, you must decide what type of “virtual circuits” to use to connect the machines. ATM is a point-to-point, switched technology; in order for two hosts to communicate, a virtual circuit must be established between them.

Switched Virtual Circuits (SVCs) are connections that are established dynamically and torn down when the connection is no longer needed. However, a high latency is associated with establishing a connection. Also, SVCs are deleted after a timeout period if no traffic is sent over the connection. Therefore, the latency associated with SVCs is not always predictable. I encountered several problems when using SVCs, such as connections not being established or sometimes failing to remain open.

Permanent Virtual Circuits (PVCs) are established and kept open. Thus, no latency is associated with establishing the connection, as there is when using SVCs. The disadvantage of PVCs is that the switch must be configured to establish all the connections between the hosts. When you have several hosts and each host needs to communicate with all the others, the number of PVCs required within the ATM switch grows rapidly. Specific configuration information for SVCs and PVCs is discussed later, but I will jump ahead a bit in order to complete the IP configuration now. The steps to configure the ATM interface are as follows:

  • Start the ATM software daemons with these commands:

     atmsigd -b
     ilmid -b
     atmarpd -b
    

  • Create the ATM device name:

     atmarp -c atm0
    

  • Configure the ATM interface for IP:

     ifconfig atm0 ipaddr netmask netmask mtu mtu
    

  • Add the route for the ATM subnet:

     route add -net network netmask netmask atm0
    

  • Create a permanent ATM ARP (address resolution protocol) cache entry for the ARP server:

     atmarp -s arpserver arpsrvnsap arpsrv
    

ipaddr is the IP address of the ATM interface, netmask is the network mask and network is the IP address of the network to which we are connecting. arpserver is the IP address of the ATM ARP server and arpsrvnsap is the ATM address of the ARP server. The ATM ARP server is used to convert an IP address to an ATM network service access point (NSAP) address. (The NSAP address is similar to a media access control (MAC) address and is 20 octets long.) The NSAP address is needed to establish SVCs between nodes. You can also create an /etc/hosts.atm file to contain the IP to NSAP mapping, allowing for quicker IP to NSAP translations. For my network, I use the Fore switch as the ARP server. The atmarpd daemon maintains a cache of IP to NSAP mappings. The atmarp command makes the ARP cache entry permanent when the arpsrv option is used.

One final note: if you are going to use PVCs only, you do not need to start the atmsigd and ilmid daemons. Listing 1 contains a complete example of configuration commands.

______________________

Comments

Comment viewing options

Select your preferred way to display the comments and click "Save settings" to activate your changes.

hi

Anonymous's picture

nice. one i like this.

Webinar
One Click, Universal Protection: Implementing Centralized Security Policies on Linux Systems

As Linux continues to play an ever increasing role in corporate data centers and institutions, ensuring the integrity and protection of these systems must be a priority. With 60% of the world's websites and an increasing share of organization's mission-critical workloads running on Linux, failing to stop malware and other advanced threats on Linux can increasingly impact an organization's reputation and bottom line.

Learn More

Sponsored by Bit9

Webinar
Linux Backup and Recovery Webinar

Most companies incorporate backup procedures for critical data, which can be restored quickly if a loss occurs. However, fewer companies are prepared for catastrophic system failures, in which they lose all data, the entire operating system, applications, settings, patches and more, reducing their system(s) to “bare metal.” After all, before data can be restored to a system, there must be a system to restore it to.

In this one hour webinar, learn how to enhance your existing backup strategies for better disaster recovery preparedness using Storix System Backup Administrator (SBAdmin), a highly flexible bare-metal recovery solution for UNIX and Linux systems.

Learn More

Sponsored by Storix